Question 1

Decay is visible in an exterior wood window frame. The window still operates, and the inspector identifies no present occupant safety hazard. Nevertheless, the inspector judges that leaving the decay uncorrected would significantly shorten the frame's expected normal life. The seller argues that a working window cannot be defective. How must the condition be classified in the Wisconsin inspection report?

Show answer & explanation

Correct answer: B - As a defect because significant loss of expected normal life is sufficient.

Question 2

An electrical inspection includes a representative sample of receptacles. Three accessible receptacles remain unchecked: two in a laundry room, 4 feet and 5 feet from the utility sink, and one in the garage, 12 feet from the nearest plumbing fixture. Which of these still require polarity and grounding checks under Wisconsin's inspection standards?

Show answer & explanation

Correct answer: D - All three, despite the representative sample already inspected.

Question 3

A Wisconsin home inspector is revising the service agreement. Which proposed provision is prohibited, rather than a permissible description of the inspection's limitations?

Show answer & explanation

Correct answer: A - Damages for the inspector's failure to meet Wisconsin standards of practice cannot exceed the inspection fee.

Question 4

A bathroom sink and bathtub each empty promptly when tested separately. When both drain together, wastewater rises through the sink drain and overflows; the inspector stops the test. Faucet flow is normal, and no connection between potable water and a contamination source is observed. Without diagnosing concealed piping, the most specific supported conclusion is:

Show answer & explanation

Correct answer: C - Functional drainage is unsatisfactory despite normal drainage when fixtures are tested separately.

Question 5

The detailed report identifies a loose hinge on a sink-base cabinet needing repair and light debris in a gutter needing routine cleaning. The inspector reasonably determines that neither is a statutory defect. The summary lists every defect and contains the required disclosures and references, but omits those two nondefect items. What correction is required before delivery?

Show answer & explanation

Correct answer: D - List both as nondefect items, cross-referenced to their detailed entries.

Question 6

An inspector subject to the full 40-credit biennial continuing education requirement has earned 30 valid credits. The inspector then attends a new qualifying workshop lasting 350 minutes, including 50 minutes of meals and breaks, and repeats a 150-minute program already included in the 30 credits. Attendance is documented. How many additional qualifying CE credits are still needed for this biennium?

Show answer & explanation

Correct answer: C - 4 credits

Question 7

From a basement doorway, an inspector sees active electrical arcing at the service panel. Reaching the main disconnect would require approaching that panel. The buyer asks the inspector to shut the power off before leaving. What should take priority?

Show answer & explanation

Correct answer: A - Withdraw, keep others clear, and summon emergency assistance without approaching the panel.

Question 8

A registered home inspector is also the real estate broker representing the seller in a transaction. The buyer wants to hire that same individual for the home inspection and offers written consent to the conflict. Which arrangement complies with Wisconsin's prohibition on the dual role?

Show answer & explanation

Correct answer: B - Use an independent registered home inspector for the inspection.

Question 9

From a safe viewing point, an inspector can clearly see separated flashing around a roof penetration serving a solar array. The solar equipment itself is excluded from the required inspection, and no interior leak is visible. The roof assessment must still:

Show answer & explanation

Correct answer: C - Describe the flashing condition despite the exclusion of the solar equipment.

Question 10

A buyer hires an inspector. The listing agent requests the report directly, but the buyer has not authorized its release. Separately, the buyer plans to send a copy to the seller during repair negotiations. The inspector says the buyer needs the inspector's permission to do so. Which statement correctly distinguishes these two disclosures?

Show answer & explanation

Correct answer: A - The inspector needs the buyer's consent to release it; the buyer may share it with the seller.